MAGENT

ACS · LIVE

ADAPT

Apply the Than 2012 ADAPT 2-hour accelerated diagnostic protocol and return whether a caller-assigned TIMI UA/NSTEMI score plus initial ECG and 0-hour/2-hour troponin flags meet the published ADP-negative (low-risk) rule.

LIVE $0.005 USDC GET /api/calc/adapt

Markdown: /docs/adapt.md · Canonical: https://magentlab.com/docs/adapt

Not a medical device. Not a diagnosis, dose, or listing recommendation.

What it computes

Apply the Than 2012 ADAPT 2-hour accelerated diagnostic protocol and return whether a caller-assigned TIMI UA/NSTEMI score plus initial ECG and 0-hour/2-hour troponin flags meet the published ADP-negative (low-risk) rule.

When to use

When an agent already has a caller-assigned Antman 2000 TIMI UA/NSTEMI total (0-7) and caller-assigned flags for new ischemic ECG changes and 0-hour and 2-hour troponin elevation and needs the published Than 2012 ADP-negative result. magent does not assign TIMI items, read an ECG, or assay troponin.

When not to use

  • Not a medical device and not a diagnosis of ACS.
  • timi_score is the caller-assigned Antman 2000 TIMI UA/NSTEMI total (0-7). magent does not assign TIMI items.
  • new_ischemic_ecg is a caller-assigned flag for new ischemic changes on the initial ECG (not known to be pre-existing). magent does not read an ECG.
  • troponin_0_elevated and troponin_2h_elevated are caller-assigned flags for 0-hour and 2-hour (not 3-hour) cTnI at or above the institutional cutoff. magent does not assay troponin.
  • This tool is not a discharge order or a stress-test order. Presence of high-risk features does not mandate a test.
  • This is the Than 2012 ADAPT protocol (TIMI 0 plus no new ischemic ECG plus both 0h/2h troponins not elevated), not HEART Pathway (Mahler 2015 HEART 0-3 plus 0h/3h) and not TIMI item scoring.

Formula

low_risk iff timi_score == 0 and new_ischemic_ecg is false and troponin_0_elevated is false and troponin_2h_elevated is false; timi_score is the caller-assigned Antman 2000 TIMI UA/NSTEMI total 0-7; ECG and troponin flags are caller-assigned (Than 2012 ADAPT Table 1)

Citation

Title
2-Hour accelerated diagnostic protocol to assess patients with chest pain symptoms using contemporary troponins as the only biomarker: the ADAPT trial
Authors
Than M, Cullen L, Aldous S, Parsonage WA, Reid CM, Greenslade J, et al.
Source
J Am Coll Cardiol. 2012;59(23):2091-2098
DOI
10.1016/j.jacc.2012.02.035

Worked example

TIMI 0, no new ischemic ECG, both troponins not elevated

Given: new_ischemic_ecg=falsetimi_score=0troponin_0_elevated=falsetroponin_2h_elevated=false

  1. timi_score 0 equals 0
  2. new_ischemic_ecg is false, troponin_0_elevated is false, and troponin_2h_elevated is false
  3. low_risk is true

Also searched as

  • ADAPT protocol
  • Than ADAPT
  • 2-hour accelerated diagnostic protocol
  • ADAPT trial
  • ADAPT ADP
  • Than 2012 chest pain
  • accelerated diagnostic protocol TIMI 0

Try

Opens the live endpoint. Unpaid browser requests show the paywall; agents should send Accept: application/json.

/api/calc/adapt?timi_score=0&new_ischemic_ecg=false&troponin_0_elevated=false&troponin_2h_elevated=false

Full URL: https://api.magentlab.com/api/calc/adapt?timi_score=0&new_ischemic_ecg=false&troponin_0_elevated=false&troponin_2h_elevated=false

Call

Expect HTTP 402 until you retry with PAYMENT-SIGNATURE. Incomplete query params return HTTP 400 before any quote or charge.

curl -i -H "Accept: application/json" "https://api.magentlab.com/api/calc/adapt?timi_score=0&new_ischemic_ecg=false&troponin_0_elevated=false&troponin_2h_elevated=false"

Parameters

Name Type Required Description
timi_score integer required Caller-assigned TIMI UA/NSTEMI score integer 0-7 (Antman 2000 components already summed by the caller). magent does not assign TIMI items. Low-risk (ADP-negative) requires 0 when the ECG and both 2-hour serial troponin flags are false.
new_ischemic_ecg boolean required New ischemic changes on the initial ECG (not known to be pre-existing), as assigned by the caller. true or false. true blocks low-risk. magent does not read an ECG.
troponin_0_elevated boolean required 0-hour cTnI at or above the institutional cutoff as assigned by the caller. true or false. true blocks low-risk. magent does not assay troponin.
troponin_2h_elevated boolean required 2-hour (not 3-hour) troponin at or above the institutional cutoff as assigned by the caller. true or false. true blocks low-risk. magent does not assay troponin.

Bulk (POST)

POST the same path with a JSON items array. The first item is the GET unit; each additional item is $0.002. Invalid items return HTTP 400 before settlement.

POST /api/calc/adapt Max 25 unit_amount + extra_item_amount * (n - 1) extra $0.002 PREVIEW

  • 1 to 25 items. Each item uses the same keys as the GET query parameters.
  • POST of 1 item costs the same as GET. Lists longer than 25: chunk into multiple POSTs. Extra items still execute; do not pad dummy rows.
  • The first invalid item fails the whole request (index in the 400 JSON). You are not charged.
  • HTTP 200 is {count, path, items}. Each items[i] is the GET 200 body for that row.
  • Catalog misses (empty matches, found=false) stay paid 200s inside that slot.
  • x402 resource URL is this path plus n and body_sha256. Browsers that prefer text/html get the same paywall as GET; Pay retries POST with the same items.

Example request (fixture)

{
  "items": [
    {
      "new_ischemic_ecg": "false",
      "timi_score": "0",
      "troponin_0_elevated": "false",
      "troponin_2h_elevated": "false"
    },
    {
      "new_ischemic_ecg": "false",
      "timi_score": "0",
      "troponin_0_elevated": "false",
      "troponin_2h_elevated": "false"
    }
  ]
}

Open bulk paywall →

Opens a two-item fixture on the API host. Unpaid browsers get the same MetaMask paywall as GET; Pay retries POST with those items.

Example 200 (fixture)

{
  "count": 2,
  "path": "/api/calc/adapt",
  "items": [
    {
      "components": [
        {
          "value": 0,
          "factor": "timi_score_eq_0",
          "met": true
        },
        {
          "value": false,
          "factor": "no_new_ischemic_ecg",
          "met": true
        },
        {
          "value": false,
          "factor": "trop0_not_elevated",
          "met": true
        },
        {
          "value": false,
          "factor": "trop2h_not_elevated",
          "met": true
        }
      ],
      "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
      "citation": {
        "authors": "Than M, Cullen L, Aldous S, Parsonage WA, Reid CM, Greenslade J, et al.",
        "doi": "10.1016/j.jacc.2012.02.035",
        "id": "than-2012",
        "pmid": "22578923",
        "source": "J Am Coll Cardiol. 2012;59(23):2091-2098",
        "title": "2-Hour accelerated diagnostic protocol to assess patients with chest pain symptoms using contemporary troponins as the only biomarker: the ADAPT trial"
      },
      "formula": "adapt",
      "formula_expression": "low_risk iff timi_score == 0 and new_ischemic_ecg is false and troponin_0_elevated is false and troponin_2h_elevated is false; timi_score is the caller-assigned Antman 2000 TIMI UA/NSTEMI total 0-7; ECG and troponin flags are caller-assigned (Than 2012 ADAPT Table 1)",
      "low_risk": true,
      "new_ischemic_ecg": false,
      "timi_score": 0,
      "troponin_0_elevated": false,
      "troponin_2h_elevated": false
    },
    {
      "components": [
        {
          "value": 0,
          "factor": "timi_score_eq_0",
          "met": true
        },
        {
          "value": false,
          "factor": "no_new_ischemic_ecg",
          "met": true
        },
        {
          "value": false,
          "factor": "trop0_not_elevated",
          "met": true
        },
        {
          "value": false,
          "factor": "trop2h_not_elevated",
          "met": true
        }
      ],
      "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
      "citation": {
        "authors": "Than M, Cullen L, Aldous S, Parsonage WA, Reid CM, Greenslade J, et al.",
        "doi": "10.1016/j.jacc.2012.02.035",
        "id": "than-2012",
        "pmid": "22578923",
        "source": "J Am Coll Cardiol. 2012;59(23):2091-2098",
        "title": "2-Hour accelerated diagnostic protocol to assess patients with chest pain symptoms using contemporary troponins as the only biomarker: the ADAPT trial"
      },
      "formula": "adapt",
      "formula_expression": "low_risk iff timi_score == 0 and new_ischemic_ecg is false and troponin_0_elevated is false and troponin_2h_elevated is false; timi_score is the caller-assigned Antman 2000 TIMI UA/NSTEMI total 0-7; ECG and troponin flags are caller-assigned (Than 2012 ADAPT Table 1)",
      "low_risk": true,
      "new_ischemic_ecg": false,
      "timi_score": 0,
      "troponin_0_elevated": false,
      "troponin_2h_elevated": false
    }
  ]
}

Response

Field Type Description
formula string adapt
formula_expression string Than 2012 ADAPT 2-hour accelerated diagnostic protocol
timi_score integer Echo of the caller-assigned TIMI UA/NSTEMI total 0-7
new_ischemic_ecg boolean Echo of the caller-assigned new ischemic ECG flag
troponin_0_elevated boolean Echo of the caller-assigned 0-hour institutional-cutoff flag
troponin_2h_elevated boolean Echo of the caller-assigned 2-hour institutional-cutoff flag
low_risk boolean true only when timi_score is 0, new_ischemic_ecg is false, and both 0-hour and 2-hour troponin flags are false. Not a discharge order or diagnosis.
components array Rows for timi_score_eq_0, no_new_ischemic_ecg, trop0_not_elevated, and trop2h_not_elevated with factor, met, and value
citation object Than 2012 J Am Coll Cardiol citation
disclaimer string Not-a-device notice

Example JSON

Machine form of the same example. Frozen fixture. Not a live lookup.

{
  "components": [
    {
      "value": 0,
      "factor": "timi_score_eq_0",
      "met": true
    },
    {
      "value": false,
      "factor": "no_new_ischemic_ecg",
      "met": true
    },
    {
      "value": false,
      "factor": "trop0_not_elevated",
      "met": true
    },
    {
      "value": false,
      "factor": "trop2h_not_elevated",
      "met": true
    }
  ],
  "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
  "citation": {
    "authors": "Than M, Cullen L, Aldous S, Parsonage WA, Reid CM, Greenslade J, et al.",
    "doi": "10.1016/j.jacc.2012.02.035",
    "id": "than-2012",
    "pmid": "22578923",
    "source": "J Am Coll Cardiol. 2012;59(23):2091-2098",
    "title": "2-Hour accelerated diagnostic protocol to assess patients with chest pain symptoms using contemporary troponins as the only biomarker: the ADAPT trial"
  },
  "formula": "adapt",
  "formula_expression": "low_risk iff timi_score == 0 and new_ischemic_ecg is false and troponin_0_elevated is false and troponin_2h_elevated is false; timi_score is the caller-assigned Antman 2000 TIMI UA/NSTEMI total 0-7; ECG and troponin flags are caller-assigned (Than 2012 ADAPT Table 1)",
  "low_risk": true,
  "new_ischemic_ecg": false,
  "timi_score": 0,
  "troponin_0_elevated": false,
  "troponin_2h_elevated": false
}

Client errors (HTTP 400)

Invalid params return 400 without charge. Shared HTTP 402 and 503 meanings: Payments.

HTTP Code When
400 invalid_timi_score timi_score must be an integer from 0 to 7 (caller-assigned Antman 2000 TIMI UA/NSTEMI total as used in Than 2012 ADAPT). Returned before settlement; you are not charged.
400 invalid_flag boolean clinical flags must be true or false Returned before settlement; you are not charged.
400 invalid_items POST body must be a JSON object with only an items array Returned before settlement; you are not charged.
400 invalid_item_count items must be an array of 1 to 25 objects Returned before settlement; you are not charged.
400 invalid_item each items entry must be a JSON object Returned before settlement; you are not charged.

Related tools

  • HEART Pathway — Apply the Mahler 2015 HEART Pathway and return whether a caller-assigned HEART score plus 0-hour and 3-hour troponin flags meet the published early-discharge rule.
  • TIMI UA/NSTEMI — Compute the TIMI risk score for unstable angina / NSTEMI from age and six caller-assigned flags.

Payment

Unpaid requests return HTTP 402 even if query parameters or POST items are missing or invalid, so CDP and agents can index the path. After a PAYMENT-SIGNATURE, invalid params return HTTP 400 JSON before settlement. magent does not charge. Fix the params, then request a new 402 quote for that complete URL. Catalog misses (empty matches, found=false) are valid paid 200s. Unpaid valid requests return HTTP 402 with a base64 PAYMENT-REQUIRED header. HTTP 503 is not a new quote: retry the same PAYMENT-SIGNATURE. Full handshake and shared payment errors: Payments. Stdio MCP: /docs/mcp.

Guarantees

  • HTTP 402 is unpaid, including a missing query. After PAYMENT-SIGNATURE, invalid parameters return HTTP 400 before settlement. You are not charged. HTTP 402 never includes the tool JSON.
  • exact: settlement finishes before the tool (paymentFlow upfront). batch-settlement: verify/deposit before the tool; chargedCumulativeAmount commits after HTTP 2xx. Uncertain or failed settlement fails closed (HTTP 503). Retry the same PAYMENT-SIGNATURE.
  • HTTP 402 is unpaid only. Do not sign a second authorization because of a 503.
  • Execution is timeout-bounded and concurrency-capped.
  • Calculator inputs are stored encrypted for allowlisted operators (Magent Console). They are not in public logs, SSH lookups, catalog, or rollups. Request logs store path without query.