ACS · LIVE
ADAPT
Apply the Than 2012 ADAPT 2-hour accelerated diagnostic protocol and return whether a caller-assigned TIMI UA/NSTEMI score plus initial ECG and 0-hour/2-hour troponin flags meet the published ADP-negative (low-risk) rule.
Markdown: /docs/adapt.md · Canonical: https://magentlab.com/docs/adapt
Not a medical device. Not a diagnosis, dose, or listing recommendation.
What it computes
Apply the Than 2012 ADAPT 2-hour accelerated diagnostic protocol and return whether a caller-assigned TIMI UA/NSTEMI score plus initial ECG and 0-hour/2-hour troponin flags meet the published ADP-negative (low-risk) rule.
When to use
When an agent already has a caller-assigned Antman 2000 TIMI UA/NSTEMI total (0-7) and caller-assigned flags for new ischemic ECG changes and 0-hour and 2-hour troponin elevation and needs the published Than 2012 ADP-negative result. magent does not assign TIMI items, read an ECG, or assay troponin.
When not to use
- Not a medical device and not a diagnosis of ACS.
- timi_score is the caller-assigned Antman 2000 TIMI UA/NSTEMI total (0-7). magent does not assign TIMI items.
- new_ischemic_ecg is a caller-assigned flag for new ischemic changes on the initial ECG (not known to be pre-existing). magent does not read an ECG.
- troponin_0_elevated and troponin_2h_elevated are caller-assigned flags for 0-hour and 2-hour (not 3-hour) cTnI at or above the institutional cutoff. magent does not assay troponin.
- This tool is not a discharge order or a stress-test order. Presence of high-risk features does not mandate a test.
- This is the Than 2012 ADAPT protocol (TIMI 0 plus no new ischemic ECG plus both 0h/2h troponins not elevated), not HEART Pathway (Mahler 2015 HEART 0-3 plus 0h/3h) and not TIMI item scoring.
Formula
low_risk iff timi_score == 0 and new_ischemic_ecg is false and troponin_0_elevated is false and troponin_2h_elevated is false; timi_score is the caller-assigned Antman 2000 TIMI UA/NSTEMI total 0-7; ECG and troponin flags are caller-assigned (Than 2012 ADAPT Table 1)
Citation
- Authors
- Than M, Cullen L, Aldous S, Parsonage WA, Reid CM, Greenslade J, et al.
- Source
- J Am Coll Cardiol. 2012;59(23):2091-2098
Worked example
TIMI 0, no new ischemic ECG, both troponins not elevated
Given:
new_ischemic_ecg=falsetimi_score=0troponin_0_elevated=falsetroponin_2h_elevated=false
- timi_score 0 equals 0
- new_ischemic_ecg is false, troponin_0_elevated is false, and troponin_2h_elevated is false
- low_risk is true
Also searched as
- ADAPT protocol
- Than ADAPT
- 2-hour accelerated diagnostic protocol
- ADAPT trial
- ADAPT ADP
- Than 2012 chest pain
- accelerated diagnostic protocol TIMI 0
Try
Opens the live endpoint. Unpaid browser requests show the paywall; agents should send Accept: application/json.
Full URL: https://api.magentlab.com/api/calc/adapt?timi_score=0&new_ischemic_ecg=false&troponin_0_elevated=false&troponin_2h_elevated=false
Call
Expect HTTP 402 until you retry with PAYMENT-SIGNATURE. Incomplete query params
return HTTP 400 before any quote or charge.
curl -i -H "Accept: application/json" "https://api.magentlab.com/api/calc/adapt?timi_score=0&new_ischemic_ecg=false&troponin_0_elevated=false&troponin_2h_elevated=false"
Parameters
| Name | Type | Required | Description |
|---|---|---|---|
timi_score |
integer | required | Caller-assigned TIMI UA/NSTEMI score integer 0-7 (Antman 2000 components already summed by the caller). magent does not assign TIMI items. Low-risk (ADP-negative) requires 0 when the ECG and both 2-hour serial troponin flags are false. |
new_ischemic_ecg |
boolean | required | New ischemic changes on the initial ECG (not known to be pre-existing), as assigned by the caller. true or false. true blocks low-risk. magent does not read an ECG. |
troponin_0_elevated |
boolean | required | 0-hour cTnI at or above the institutional cutoff as assigned by the caller. true or false. true blocks low-risk. magent does not assay troponin. |
troponin_2h_elevated |
boolean | required | 2-hour (not 3-hour) troponin at or above the institutional cutoff as assigned by the caller. true or false. true blocks low-risk. magent does not assay troponin. |
Bulk (POST)
POST the same path with a JSON items array. The first item is the GET unit; each additional item is $0.002. Invalid items return HTTP 400 before settlement.
- 1 to 25 items. Each item uses the same keys as the GET query parameters.
- POST of 1 item costs the same as GET. Lists longer than 25: chunk into multiple POSTs. Extra items still execute; do not pad dummy rows.
- The first invalid item fails the whole request (index in the 400 JSON). You are not charged.
- HTTP 200 is {count, path, items}. Each items[i] is the GET 200 body for that row.
- Catalog misses (empty matches, found=false) stay paid 200s inside that slot.
- x402 resource URL is this path plus n and body_sha256. Browsers that prefer text/html get the same paywall as GET; Pay retries POST with the same items.
Example request (fixture)
{
"items": [
{
"new_ischemic_ecg": "false",
"timi_score": "0",
"troponin_0_elevated": "false",
"troponin_2h_elevated": "false"
},
{
"new_ischemic_ecg": "false",
"timi_score": "0",
"troponin_0_elevated": "false",
"troponin_2h_elevated": "false"
}
]
}
Opens a two-item fixture on the API host. Unpaid browsers get the same MetaMask paywall as GET; Pay retries POST with those items.
Example 200 (fixture)
{
"count": 2,
"path": "/api/calc/adapt",
"items": [
{
"components": [
{
"value": 0,
"factor": "timi_score_eq_0",
"met": true
},
{
"value": false,
"factor": "no_new_ischemic_ecg",
"met": true
},
{
"value": false,
"factor": "trop0_not_elevated",
"met": true
},
{
"value": false,
"factor": "trop2h_not_elevated",
"met": true
}
],
"disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
"citation": {
"authors": "Than M, Cullen L, Aldous S, Parsonage WA, Reid CM, Greenslade J, et al.",
"doi": "10.1016/j.jacc.2012.02.035",
"id": "than-2012",
"pmid": "22578923",
"source": "J Am Coll Cardiol. 2012;59(23):2091-2098",
"title": "2-Hour accelerated diagnostic protocol to assess patients with chest pain symptoms using contemporary troponins as the only biomarker: the ADAPT trial"
},
"formula": "adapt",
"formula_expression": "low_risk iff timi_score == 0 and new_ischemic_ecg is false and troponin_0_elevated is false and troponin_2h_elevated is false; timi_score is the caller-assigned Antman 2000 TIMI UA/NSTEMI total 0-7; ECG and troponin flags are caller-assigned (Than 2012 ADAPT Table 1)",
"low_risk": true,
"new_ischemic_ecg": false,
"timi_score": 0,
"troponin_0_elevated": false,
"troponin_2h_elevated": false
},
{
"components": [
{
"value": 0,
"factor": "timi_score_eq_0",
"met": true
},
{
"value": false,
"factor": "no_new_ischemic_ecg",
"met": true
},
{
"value": false,
"factor": "trop0_not_elevated",
"met": true
},
{
"value": false,
"factor": "trop2h_not_elevated",
"met": true
}
],
"disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
"citation": {
"authors": "Than M, Cullen L, Aldous S, Parsonage WA, Reid CM, Greenslade J, et al.",
"doi": "10.1016/j.jacc.2012.02.035",
"id": "than-2012",
"pmid": "22578923",
"source": "J Am Coll Cardiol. 2012;59(23):2091-2098",
"title": "2-Hour accelerated diagnostic protocol to assess patients with chest pain symptoms using contemporary troponins as the only biomarker: the ADAPT trial"
},
"formula": "adapt",
"formula_expression": "low_risk iff timi_score == 0 and new_ischemic_ecg is false and troponin_0_elevated is false and troponin_2h_elevated is false; timi_score is the caller-assigned Antman 2000 TIMI UA/NSTEMI total 0-7; ECG and troponin flags are caller-assigned (Than 2012 ADAPT Table 1)",
"low_risk": true,
"new_ischemic_ecg": false,
"timi_score": 0,
"troponin_0_elevated": false,
"troponin_2h_elevated": false
}
]
}
Response
| Field | Type | Description |
|---|---|---|
formula |
string | adapt |
formula_expression |
string | Than 2012 ADAPT 2-hour accelerated diagnostic protocol |
timi_score |
integer | Echo of the caller-assigned TIMI UA/NSTEMI total 0-7 |
new_ischemic_ecg |
boolean | Echo of the caller-assigned new ischemic ECG flag |
troponin_0_elevated |
boolean | Echo of the caller-assigned 0-hour institutional-cutoff flag |
troponin_2h_elevated |
boolean | Echo of the caller-assigned 2-hour institutional-cutoff flag |
low_risk |
boolean | true only when timi_score is 0, new_ischemic_ecg is false, and both 0-hour and 2-hour troponin flags are false. Not a discharge order or diagnosis. |
components |
array | Rows for timi_score_eq_0, no_new_ischemic_ecg, trop0_not_elevated, and trop2h_not_elevated with factor, met, and value |
citation |
object | Than 2012 J Am Coll Cardiol citation |
disclaimer |
string | Not-a-device notice |
Example JSON
Machine form of the same example. Frozen fixture. Not a live lookup.
{
"components": [
{
"value": 0,
"factor": "timi_score_eq_0",
"met": true
},
{
"value": false,
"factor": "no_new_ischemic_ecg",
"met": true
},
{
"value": false,
"factor": "trop0_not_elevated",
"met": true
},
{
"value": false,
"factor": "trop2h_not_elevated",
"met": true
}
],
"disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
"citation": {
"authors": "Than M, Cullen L, Aldous S, Parsonage WA, Reid CM, Greenslade J, et al.",
"doi": "10.1016/j.jacc.2012.02.035",
"id": "than-2012",
"pmid": "22578923",
"source": "J Am Coll Cardiol. 2012;59(23):2091-2098",
"title": "2-Hour accelerated diagnostic protocol to assess patients with chest pain symptoms using contemporary troponins as the only biomarker: the ADAPT trial"
},
"formula": "adapt",
"formula_expression": "low_risk iff timi_score == 0 and new_ischemic_ecg is false and troponin_0_elevated is false and troponin_2h_elevated is false; timi_score is the caller-assigned Antman 2000 TIMI UA/NSTEMI total 0-7; ECG and troponin flags are caller-assigned (Than 2012 ADAPT Table 1)",
"low_risk": true,
"new_ischemic_ecg": false,
"timi_score": 0,
"troponin_0_elevated": false,
"troponin_2h_elevated": false
}
Client errors (HTTP 400)
Invalid params return 400 without charge. Shared HTTP 402 and 503 meanings: Payments.
| HTTP | Code | When |
|---|---|---|
| 400 | invalid_timi_score |
timi_score must be an integer from 0 to 7 (caller-assigned Antman 2000 TIMI UA/NSTEMI total as used in Than 2012 ADAPT). Returned before settlement; you are not charged. |
| 400 | invalid_flag |
boolean clinical flags must be true or false Returned before settlement; you are not charged. |
| 400 | invalid_items |
POST body must be a JSON object with only an items array Returned before settlement; you are not charged. |
| 400 | invalid_item_count |
items must be an array of 1 to 25 objects Returned before settlement; you are not charged. |
| 400 | invalid_item |
each items entry must be a JSON object Returned before settlement; you are not charged. |
Related tools
- HEART Pathway — Apply the Mahler 2015 HEART Pathway and return whether a caller-assigned HEART score plus 0-hour and 3-hour troponin flags meet the published early-discharge rule.
- TIMI UA/NSTEMI — Compute the TIMI risk score for unstable angina / NSTEMI from age and six caller-assigned flags.
Payment
Unpaid requests return HTTP 402 even if query parameters or POST items are missing or invalid, so CDP and agents can index the path. After a PAYMENT-SIGNATURE, invalid params return HTTP 400 JSON before settlement. magent does not charge. Fix the params, then request a new 402 quote for that complete URL. Catalog misses (empty matches, found=false) are valid paid 200s. Unpaid valid requests return HTTP 402 with a base64
PAYMENT-REQUIRED
header. HTTP 503 is not a new quote: retry the same PAYMENT-SIGNATURE. Full handshake
and shared payment errors: Payments.
Stdio MCP: /docs/mcp.
Guarantees
- HTTP 402 is unpaid, including a missing query. After PAYMENT-SIGNATURE, invalid parameters return HTTP 400 before settlement. You are not charged. HTTP 402 never includes the tool JSON.
- exact: settlement finishes before the tool (paymentFlow upfront). batch-settlement: verify/deposit before the tool; chargedCumulativeAmount commits after HTTP 2xx. Uncertain or failed settlement fails closed (HTTP 503). Retry the same PAYMENT-SIGNATURE.
- HTTP 402 is unpaid only. Do not sign a second authorization because of a 503.
- Execution is timeout-bounded and concurrency-capped.
- Calculator inputs are stored encrypted for allowlisted operators (Magent Console). They are not in public logs, SSH lookups, catalog, or rollups. Request logs store path without query.